KODAK
INVERTER GUIDE
+ SETTINGS + COMMUNICATION + TROUBLESHOOTING
The Kodak Off-Grid inverters are fully compatible with the Hubble range of batteries.
The following field guide will assist with the correct battery settings you should use.
For further detailed information ensure you read the manual of the supplied battery regarding setup and installation instructions.
WARNING
Working with high-voltage systems is dangerous. Do not attempt to modify your inverter and battery setup unless you are certain you understand the risk. Speak to a qualified electrician if you are unsure.
INVERTER EXAMPLE
INVERTER SETTINGS
Model | Voltage | Equalised | Float | Cutoff | Charge Amps | Max Discharge Current |
---|---|---|---|---|---|---|
S-SERIES | 12V | 14 | 14 | 12 | 30A | 100A |
X-100 | 48V | 52.8 | 52.8 | 44 | 30A | 100A |
X-101 | 48V | 53.8 | 53.8 | 44 | 30A | 100A |
X-200 | 36V | 41.5 | 41.5 | 34 | 30A | 100A |
AM-2 | 48V | 53.8 | 53.8 | 44 | 30A | 100A |
AM-3 | 48V | 53.8 | 53.8 | 44 | 20A | 50A |
AM-4 | 24V | 29 | 28.5 | 22 | 30A | 100A |
AM-5 | 48V | 55.2 | 55.2 | 47 | 30A | 100A |
AM-10 | 48V | 55.2 | 55.2 | 47 | 60A | 150A |
BLADE | 48V | 55.2 | 55.2 | 47 | 50A | 200A |
PIN LAYOUTS & CLOUDLINK
PLEASE NOTE
Axpert type inverters require a Cloudlink to access full CAN-BUS communication with a Hubble Energy battery, it is however not required, and the system will be functional on user defined voltage control.
CLOUDLINK
The Cloudlink will connect to a Kodak Inverter via:
Cloudlink’s (Serial/RJ12 Port) to the Kodak Inverter (RS232 Port)
(Black Cable) - Serial/RJ12 to RJ45 (450mm) cable.
The Cloudlink will connect to the Battery via:
Cloudlink’s (CAN Port) to the Battery (CAN Port)
(Blue Cable) - Standard RJ45 to RJ45 (1500mm) cable.
RJ45 PIN LAYOUTS
Ensure that the clip is pointed away from you when counting the pins.
PIN | X-101/AM-4/AM-2 | AM-5/AM-10 |
---|---|---|
1 | - | - |
2 | GROUND | - |
3 | - | - |
4 | CANH | CANH |
5 | CANL | CANL |
6 | - | |
7 | - | - |
8 | - | - |
2, 4 & 5 Pin Layout image reference seen below: (Blue Cable)
4 & 5 Pin Layout image reference seen below: (Blue Cable - Modified)
HUBBLE DIP SWITCH SETTINGS
FOR MULTIPLE BATTERY INSTALLATION
For correct setup and communication, each battery needs a unique serial address to communicate. If you are only using one battery in your setup, consider this the master battery and ensure you set it to address 1.
AM-2, AM- 4 & BLADE DIP SWITCHES
ADDRESS | SWITCH POSITIONS | SWITCH POSITIONS | SWITCH POSITIONS | SWITCH POSITIONS |
---|---|---|---|---|
#1 | #2 | #3 | #4 | |
1 | ON | OFF | OFF | OFF |
2 | OFF | ON | OFF | OFF |
3 | ON | ON | OFF | OFF |
4 | OFF | OFF | ON | OFF |
5 | ON | OFF | ON | OFF |
6 | OFF | ON | ON | OFF |
7 | ON | ON | ON | OFF |
8 | OFF | OFF | OFF | ON |
9 | ON | OFF | OFF | ON |
10 | OFF | ON | OFF | ON |
11 | ON | ON | OFF | ON |
12 | OFF | OFF | ON | ON |
13 | ON | OFF | ON | ON |
14 | OFF | ON | ON | ON |
15 | ON | ON | ON | ON |
AM-5 & AM-10 DIP SWITCHES (4-DIP VERSION)
ADDRESS | SWITCH POSITIONS | SWITCH POSITIONS | SWITCH POSITIONS | SWITCH POSITIONS |
---|---|---|---|---|
#1 | #2 | #3 | #4 | |
1 | OFF | OFF | OFF | OFF |
2 | ON | OFF | OFF | OFF |
3 | OFF | ON | OFF | OFF |
4 | ON | ON | OFF | OFF |
5 | OFF | OFF | ON | OFF |
6 | ON | OFF | ON | OFF |
7 | OFF | ON | ON | OFF |
8 | ON | ON | ON | OFF |
9 | OFF | OFF | OFF | ON |
10 | ON | OFF | OFF | ON |
11 | OFF | ON | OFF | ON |
12 | ON | ON | OFF | ON |
13 | OFF | OFF | ON | ON |
14 | OFF | ON | ON | ON |
15 | ON | ON | ON | ON |
AM-10 (8-DIP VERSION)
ADDRESS | SWITCH POSITIONS | SWITCH SETTINGS | SWITCH SETTINGS | SWITCH SETTINGS | SWITCH SETTINGS | SWITCH SETTINGS | SWITCH SETTINGS |
---|---|---|---|---|---|---|---|
#1 | #2 | #3 | #4 | #5 | #6 | Mark (#7 & #8) | |
0 | ON | ON | OFF | OFF | OFF | OFF | Mastery Battery/Enable CAN BUS Port - ON |
1 | OFF | OFF | OFF | OFF | OFF | OFF | Slave 2 - OFF |
2 | OFF | ON | OFF | OFF | OFF | OFF | Slave 3 - OFF |
3 | OFF | OFF | ON | OFF | OFF | OFF | Slave 4 - OFF |
4 | OFF | ON | ON | OFF | OFF | OFF | Slave 5 - OFF |
5 | OFF | OFF | OFF | ON | OFF | OFF | Slave 6 - OFF |
6 | OFF | ON | OFF | ON | OFF | OFF | Slave 7 - OFF |
7 | OFF | OFF | ON | ON | OFF | OFF | Slave 8 - OFF |
8 | OFF | ON | ON | ON | OFF | OFF | Slave 9 - OFF |
9 | OFF | OFF | OFF | OFF | ON | OFF | Slave 10 - OFF |
10 | OFF | ON | OFF | OFF | ON | OFF | Slave 11 - OFF |
11 | OFF | OFF | ON | OFF | ON | OFF | Slave 12 - OFF |
12 | OFF | ON | ON | OFF | ON | OFF | Slave 13 - OFF |
13 | OFF | OFF | OFF | ON | ON | OFF | Slave 14 - OFF |
14 | OFF | ON | OFF | ON | ON | OFF | Slave 15 - OFF |